Feeney Sales Binder 2024

ASSEMBLY DIAGRAMS

ERA® BASE KIT

ERA® EXTENSION KIT

14.03"

14.03"

39.13"

14.03"

39.13"

39.13"

39.13"

AWNING SNOW LOAD MAP (v03/19) (U.S. SNOW LOADS PER 2018 IBC)

Washington 10-20 PSF (*CS)

Montana 20-30 PSF (*CS)

Maine 50-100 PSF

Each Era extension kit adds 56-5/8” to the overall length of the awning assembly: Era ® Base Kit + 1 Era ® Extenstion Kit = 115.625” Era ® Base Kit + 2 Era ® Extenstion Kits = 172.25” Era ® Base Kit + 3 Era ® Extenstion Kits = 228.875”

North Dakota 30-60 PSF

Oregon 5-20 PSF (*CS)

Minnesota 40-70 PSF

Vermont 40-60 PSF

Idaho 10-20 PSF (*CS)

New Hampshire 50-90 PSF

South Dakota 15-50 PSF (*CS)

New York 25-50 PSF (*CS)

Massachusetts 35-60 PSF

Wisconsin 25-60 PSF (*CS)

Wyoming 15-20 PSF (*CS)

Michigan 20-70 PSF (*CS)

Rhode Island 25-40 PSF

Connecticut 30-40 PSF

Pennsylvania 25-35 PSF (*CS)

Iowa 20-40 PSF

New Jersey 20-30 PSF (*CS)

Nebraska 20-40 PSF (*CS)

Nevada 0-20 PSF (*CS)

Ohio 20-25 PSF (*CS)

Indiana 15-30 PSF (*CS)

Illinois 15-30 PSF

Utah 10-35 PSF (*CS)

Delaware 20-25 PSF

West Virginia 20-30 PSF (*CS)

Colorado 10-35 PSF (*CS)

Maryland 15-30 PSF (*CS)

California 0-15 PSF (*CS)

Virginia 10-30 PSF (*CS)

Kansas 15-25 PSF

Missouri 10-20 PSF

Kentucky 15-20 PSF (*CS)

North Carolina 10-25 PSF (*CS)

Tennessee 10-25 PSF

Arizona 0-15 PSF (*CS)

Oklahoma 5-20 PSF

New Mexico 0-15 PSF (*CS)

South Carolina 0-15 PSF (*CS)

Arkansas 5-15 PSF

Georgia 0-10 PSF (*CS)

Alabama 0-10 PSF

Mississippi 0-10 PSF

Louisiana 0-5 PSF

Texas 0-20 PSF

Florida 0 PSF

- Meets Snow Load Requirment for En � re State** - Meets Snow Load Requirment in Some Areas of State - Does not Meet Snow Load Requrirment in Any Part of State

(*CS) - State has 'Case Study' Snow Load requirements, typically applicable for areas in higher eleva � ons. These requirements will vary and may be greater than the listed range for that state's Snow Load. **- Always check with local building code jurisidic � ons. Some states, coun � es or ci � es may have amended the IBC snow load requirments and will have di ff erent requirements then what is shown on map.

Feeney Awnings are Engineerd to meet a Snow Load of 35.5psf See the snow load map on our website

ALUMINUM FRAME SPECIFICATIONS

Extrusion/Finish Type

Alloy

Specification ASTM B221

Awning Frame

6060-T5

ASTM B221 AMSQQA200/9

Screw Caps

6063-T6

Powder-Coating

AAMA 2604

FASTENER SPECIFICATIONS

Fastener

Material

Specification

Lag Screws

Type 18-8 Stainless Steel

ANSI/ASME B18.2.1-2012

PANEL SPECIFICATIONS

MAINTENANCE GUIDELINES Feeney Awnings should be cleaned periodically. Cleaning frequency will depend on the environmental conditions that the product is placed in. Feeney recommends using warm water and mild soap. Rinse your Awning with fresh water. Remove dust and dirt with a soft cloth or sponge and a solution of mild soap and/or liquid detergent in water. Always use a soft, damp cloth to blot dry. Avoid harsh solutions or abrasive cleaning compounds, included but not limited to: alkaline or acidic cleaners, solutions containing trisodium phosphate, phosphoric acid, hydroflouric acid, gasoline, benzene, acetone, carbon tetrachloride, certain deicing fluids, lacquer thinner or other strong solvents. Product should be cleaned when the awning is shaded.

Material

Specification

Polycarbonate

ANSI/FM 4473 Class 4 (highest) impact rating

See Warranty and Care brochure or scan the QR code to learn more about our product maintenance guidelines and warranty information.

FEENEY IS A PROUD MEMBER OF:

© 2025 Feeney, Inc. Consistent with our policy of continuing product improvement, we reserve the right to change product specifications without notice or obligation. v2/25 EXECUTIVE BOARD